Installation instructions, Warning, Leveling and stabilizing your dryer – GE GTDX185EDCC User Manual

Page 4: Exhaust information (cont)

Advertising
background image

Installation Instructions

4

5

LEVELING AND STABILIZING YOUR DRYER

LEVEL
SIDE-TO-SIDE.

4 LEVELING LEGS

LEVEL
FRONT-TO-BACK.

EXHAUST INFORMATION (cont)

SEALING OF JOINTS
• All joints should be tight to avoid leaks. The male end of

each section of duct must point away from the dryer.

• Do not assemble the ductwork with fasteners that

extend into the duct. They will serve as a collection point
for lint.

‡ 'XFW MRLQWV FDQ EH PDGH DLU DQG PRLVWXUHWLJKW E\

wrapping the overlapped joints with duct tape.

‡ +RUL]RQWDOUXQVVKRXOGVORSHGRZQWRZDUGWKHRXWGRRUV

1/4 inch per foot

INSULATION
Duct work that runs through an unheated area or is near air
conditioning should be insulated to reduce condensation
DQGOLQWEXLOGXS

NOTE: WE STRONGLY RECOMMEND SOLID METAL EXHAUST DUCTING.
HOWEVER, IF FLEXIBLE DUCTING IS USED IT MUST BE UL-LISTED METAL
NOT PLASTIC.

DUCT TAPE OR
DUCT CLAMP

4” METAL DUCT
(CUT TO PROPER
LENGTH)

DUCT TAPE OR
DUCT CLAMP

EXTERNAL
DUCT
OPENING

FOR STRAIGHT LINE INSTALLATION,
CONNECT THE DRYER EXHAUST TO
THE EXTERNAL EXHAUST HOOD
USING DUCT TAPE OR CLAMP.

STANDARD REAR EXHAUST

(Vented at floor level)

4

EXHAUST CONNECTION

THIS DRYER COMES READY FOR REAR
EXHAUSTING. IF SPACE IS LIMITED, USE
THE INSTRUCTIONS IN SECTION 10 TO
EXHAUST DIRECTLY FROM THE SIDES
OR BOTTOM OF THE CABINET.

WARNING -

TO REDUCE THE

RISK OF FIRE OR PERSONAL INJURY:

• This clothes dryer must be exhausted to the

outdoors.

• Use only 4” rigid metal ducting for the home exhaust

duct.

‡ 8VH RQO\ µ ULJLG PHWDO RU 8/OLVWHG ÀH[LEOH PHWDO

VHPLULJLG RU IRLOW\SH  GXFW WR FRQQHFW WKH GU\HU

to the home exhaust duct. It must be installed
in accordance with the instructions found in
“Connecting The Dryer To House Vent” on page 5 of
this manual.

• Do not terminate exhaust in a chimney, a wall,

a ceiling, gas vent, crawl space, attic, under an
HQFORVHG ÀRRU RU LQ DQ\ RWKHU FRQFHDOHG VSDFH

of a building. The accumulated lint could create a
SRWHQWLDO¿UHKD]DUG

• Never terminate the exhaust into a common duct

with a kitchen exhaust system. A combination of
JUHDVHDQGOLQWFUHDWHVDSRWHQWLDO¿UHKD]DUG

‡ 'RQRWXVHGXFWORQJHUWKDQVSHFL¿HGLQWKHH[KDXVW

length table. Longer ducts can accumulate lint,
FUHDWLQJDSRWHQWLDO¿UHKD]DUG

• Never install a screen in or over the exhaust duct.

This will cause lint to accumulate, creating a
SRWHQWLDO¿UHKD]DUG

• Do not assemble ductwork with any fasteners

that extend into the duct. These fasteners can
DFFXPXODWHOLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG

• Do not obstruct incoming or exhausted air.
• Provide an access for inspection and cleaning of

the exhaust system, especially at turns and joints.
Exhaust system shall be inspected and cleaned at
least once a year.

RECOMMENDED
CONFIGURATION
TO MINIMIZE
EXHAUST
BLOCKAGE.

ELBOW HIGHLY
RECOMMENDED

ELBOW HIGHLY
RECOMMENDED

NOTE: ELBOWS WILL PREVENT DUCT
KINKING AND COLLAPSING.

STANDARD REAR EXHAUST
(Vented above floor level)

Advertising