Installation Instructions

2

Minimum Clearance Other Than Alcove or Closet Installation

0LQLPXPFOHDUDQFHWRFRPEXVWLEOHVXUIDFHVDQGIRUDLURSHQLQJDUHLQFOHDUDQFHERWKVLGHVDQGLQUHDU

Consideration must be given to provide adequate clearance for installation and service.

1

PREPARING FOR INSTALLATION

OF NEW DRYER

7,3,QVWDOO\RXUGU\HUEHIRUHLQVWDOOLQJ\RXUZDVKHU

This will allow better access when installing dryer
H[KDXVW

DISCONNECTING GAS

WARNING

- NEVER REUSE

2/')/(;,%/(&211(&7256

7KHXVHRIROGÀH[LEOHFRQQHFWRUVFDQFDXVHOHDNV
DQGSHUVRQDOLQMXU\$OZD\VXVHQHZÀH[LEOH

connectors when installing gas appliances.

REMOVING LINT FROM WALL EXHAUST

OPENING

• Remove and discard existing plastic or metal foil

transition duct and replace with UL listed transition
duct.

INTERNAL DUCT
OPENING

CHECK THAT EXHAUST
HOOD DAMPER OPENS
AND CLOSES FREELY.

WALL

TILT THE DRYER SIDEWAYS
AND REMOVE THE FOAM
SHIPPING PADS BY
PULLING AT THE SIDES
AND BREAKING THEM
AWAY FROM THE DRYER
LEGS. BE SURE TO
REMOVE ALL OF THE
FOAM PIECES AROUND
THE LEGS.

TURN GAS
SHUT-OFF
VALVE TO THE
OFF POSITION.

DISCONNECT AND DISCARD OLD

FLEXIBLE GAS CONNECTOR AND

OLD DUCTING MATERIAL.

REPLACE WITH NEW CSA(AGA)

APPROVED FLEXIBLE GAS LINE

CONNECTOR AND UL APPROVED

TRANSITION DUCT.

2

GAS REQUIREMENTS

WARNING

• Installation must conform to local codes and

ordinances,or in their absence, the NATIONAL FUEL

GAS CODE,ANSI Z223.

• 7KLV JDV GU\HU LV HTXLSSHG ZLWK D 9DOYH  %XUQHU

Assembly for use only with natural gas. Using conversion
NLW :(; \RXU ORFDO VHUYLFH RUJDQL]DWLRQ FDQ
FRQYHUW WKLV GU\HU IRU XVH ZLWK SURSDQH /3  JDV $//
&219(56,216 0867 %( 0$'( %< 3523(5/< 75$,1('

AND QUALIFIED PERSONNEL AND IN ACCORDANCE WITH

LOCAL CODES AND ORDINANCE REQUIREMENTS.

• The dryer must be disconnected from the gas supply

piping system during any pressure testing of that
V\VWHPDWDWHVWSUHVVXUHLQH[FHVVRI36, .3D 

• The dryer must be isolated from the gas supply piping

V\VWHPE\FORVLQJWKHHTXLSPHQWVKXWRȺYDOYHGXULQJ

any pressure testing of the gas supply piping of test
SUHVVXUHHTXDOWRRUOHVVWKDQ36, .3D 

DRYER GAS SUPPLY CONNECTION

• $LQ1DWLRQDO3LSH7DSHUWKUHDGSOXJJHGWDSSLQJ

accessible for test gauge connection, must be installed

immediately upstream of the gas supply connection to

the dryer. Contact your local gas utility should you have

questions on the installation of the plugged tapping.

• 6XSSO\OLQHLVWREHLQULJLGSLSHDQGHTXLSSHGZLWK

DQDFFHVVLEOHVKXWRȺZLWKLQIWRIDQGLQWKHVDPH

room with the dryer.

• Use pipe thread sealer compound appropriate for

QDWXUDORU/3JDVRUXVH7HÀRQWDSH

• <RXPXVWXVHZLWKWKLVGU\HUDÀH[LEOHPHWDOFRQQHFWRU

OLVWHGFRQQHFWRU$16,=&6$ 7KHOHQJWKRI

the connect shall not exceed 3 ft.

• &RQQHFWÀH[LEOHPHWDOFRQQHFWRUWRGU\HUDQGJDVVXSSO\

• 2SHQVKXWRȺYDOYH

• Gas clothes dryers input ratings are based on sea level

operation and need not be adjusted for operation at or

below 2000 ft. elevation.

For operation at elevations above 2000 ft., input ratings
VKRXOGEHUHGXFHGDWDUDWHRISHUFHQWIRUHDFK

ft. above sea level.

• Installation must conform to local codes and ordinances

or, in their absence, the NATIONAL FUEL GAS CODE, ANSI

Z223.

ADJUSTING FOR ELEVATION

2"

2-5/8"

3/8" NPT MALE THREAD GAS SUPPLY

NOTE: Add to vertical dimension

the distance between cabinet

bottom to floor.