Installation instructions, Warning, Exhaust information – GE GTDL210GDWW User Manual

Page 4: Electrical requirements, Exhaust system check list, Electrical connection information

Advertising
background image



EXHAUST INFORMATION

WARNING -

IN CANADA AND IN

THE UNITED STATES, THE REQUIRED EXHAUST
'8&7 ',$0(7(5 ,6  LQ PP  '2 127

USE DUCT LONGER THAN SPECIFIED IN THE
(;+$867/(1*7+7$%/(

8VLQJH[KDXVWORQJHUWKDQVSHFL¿HGOHQJWKZLOO

• Increase the drying times and the energy cost.
• Reduce the dryer life.
‡$FFXPXODWHOLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG

The correct exhaust installation is YOUR RESPONSIBILITY

Problems due to incorrect installation are not covered
E\WKHZDUUDQW\

Remove and discard existing plastic or metal foil
transition duct and replace with UL listed transition duct.
The MAXIMUM ALLOWABLE duct length and number of
bends of the exhaust system depends upon the type of
GXFW QXPEHU RI WXUQV WKH W\SH RI H[KDXVW KRRG ZDOO
FDS DQGDOOFRQGLWLRQVQRWHGEHORZ7KHPD[LPXPGXFW

length for rigid metal duct is shown in the table below.

4" DIA.

4"

4" DIA.

4" DIA.

2-1/2"

RECOMMENDED MAXIMUM LENGTH

Exhaust Hood Types

Recommended

No. of 90°

Elbows

Rigid

Metal

Rigid

Metal

90 Feet
60 Feet
45 Feet
35 Feet
25 Feet

60 Feet
45 Feet
35 Feet
25 Feet
15 Feet

0
1
2
3
4

Use only for short

run installations

EXHAUST LENGTH



ELECTRICAL CONNECTION

INFORMATION

WARNING

- TO REDUCE THE

RISK OF FIRE, ELECTRICAL SHOCK,

AND PERSONAL INJURY:

• DO NOT USE AN EXTENSION CORD

OR AN ADAPTER PLUG WITH THIS
$33/,$1&(

Dryer must be electrically grounded in accordance
with local codes and ordinances, or in the absence
of local codes, in accordance with the NATIONAL
(/(&75,&$/&2'($16,1)3$12

ELECTRICAL REQUIREMENTS

7KLVDSSOLDQFHPXVWEHVXSSOLHGZLWK9+]DQG

connected to a properly grounded branch circuit,
SURWHFWHGE\DRUDPSFLUFXLWEUHDNHURUWLPH
GHOD\IXVH,IHOHFWULFDOVXSSO\SURYLGHGGRHVQRWPHHW
WKH DERYH VSHFL¿FDWLRQV LW LV UHFRPPHQGHG WKDW D
OLFHQVHGHOHFWULFLDQLQVWDOODQDSSURYHGRXWOHW

WARNING

- THIS DRYER IS

EQUIPPED WITH A THREE-PRONG
*5281',1*  3/8* )25 <285

PROTECTION AGAINST SHOCK HAZARD

AND SHOULD BE PLUGGED DIRECTLY

INTO A PROPERLY GROUNDED THREE-
3521*5(&(37$&/('2127&8725

REMOVE THE GROUNDING PRONG
)5207+,63/8*

LOCAL CODES PERMIT,

N EXTERNAL GROUND WIRE

OT PROVIDED), WHICH MEETS

OCAL CODES, MAY BE ADDED

Y ATTACHING TO THE GREEN

ROUND SCREW ON THE REAR
F THE DRYER, AND TO A GROUNDED

ETAL COLD WATER PIPE OR OTHER

STABLISHED GROUND.

ENSURE PROPER GROUND EXISTS BEFORE USE

• For every extra 90° elbow, reduce the allowable vent system

OHQJWKE\IW

• Two 45° elbows will be treated like one 90° elbow.

• For the side exhaust installations, add one 90° elbow to the

chart.

• The total vent system length includes all the straight

SRUWLRQVDQGHOERZVRIWKHV\VWHP WUDQVLWLRQGXFWLQFOXGHG 

EXHAUST SYSTEM CHECK LIST

HOOD OR WALL CAP

• Terminate in a manner to prevent back drafts or entry of

birds or other wildlife.

• Termination should present minimal resistance to the

H[KDXVWDLUÀRZDQGVKRXOGUHTXLUHOLWWOHRUQRPDLQWHQDQFH

to prevent clogging.

• Never install a screen in or over the exhaust duct. This

could cause lint build up.

‡ :DOOFDSVPXVWEHLQVWDOOHGDWOHDVWLQDERYHJURXQG

level or any other obstruction with the opening pointed

down.

SEPARATION OF TURNS

For best performance, separate all turns by at least 4 ft. of

straight duct, including distance between last turn and

exhaust hood.

TURNS OTHER THAN 90º

• One turn of 45º or less may be ignored.

• Two 45º turns should be treated as one 90º turn.

• Each turn over 45º should be treated as one 90º turn.

Installation Instructions

4