Design guide, Clearances – GE ZIRP360NXLH User Manual

Page 4

Advertising
background image

Design Guide

4

7KHVHXQLWVDUHHTXLSSHGZLWKDSRVLWLRQGRRUVWRS
7KHIDFWRU\VHWƒGRRUVZLQJFDQEHDGMXVWHGWRƒ

if clearance to adjacent cabinets or walls is restricted.
Order WX14X99 door stop for precise settings between
90° and 130°.

When Installed into a corner:
Allow 25” for a full 130° door swing. Allow 15” for pan
removal. Allow 4” min. clearance when door swing
is adjusted to a 90° opening for pan access, but pan
removal is restricted.

25"

Min. to

Wall

130

°

130

° Door

Swing

CLEARANCES

ZUG2, ZUGSS2 Unified Grille Panel Kit
‡,I\RXDUHLQVWDOOLQJWZRXQLWVVLGHE\VLGH

WKHLQVWDOODWLRQVSDFHPXVWEHµZLGH

Note: Additional cutout width may be required when

side panels are used. Add side panel thickness

to the finished cutout to calculate rough-in width.


‡7KHZDWHUDQGHOHFWULFDOORFDWLRQVIRUHDFKSURGXFW

must be located as shown.

‡$VHSDUDWH9+]RUDPSSRZHUVXSSO\

is recommended for each product.

Clearances for Multiple Single Door Installations
In a side-by-side installation of a left and right door
swing product, a 1” clearance between the units is
UHTXLUHG2UGHU=8*666WDLQOHVV6WHHO8QLILHG*ULOOH
3DQHO.LWRU=8*&XVWRP3DQHO8QLILHG*ULOOH3DQHO.LW

for one continuous grille panel.

Clearances for two products installed side-by-side
with the same (left or right) door swing

Allow 2” minimum clearance between the products
to prevent door swing interference. Order the WX14X99
adjustable door stop to reduce the factory set 130°
door swing. Allow 15” minimum to a wall to achieve
full drawer extension and pan removal.
NOTE: =8*DQG=8*66*ULOOH3DQHO.LWZLOONOT fit this

installation.

2"

15"

Clearances for two products installed side-by-side
with right and left side hinges together

Allow 5” minimum between the two products to prevent
RQHGRRUIURPVWULNLQJWKHRWKHU8VHWKH:;;

adjustable door stop to reduce the factory set 130°
door swing and to allow pan removal.
NOTE: =8*DQG=8*66*ULOOH3DQHO.LWZLOO127ILWWKLV

installation.

5"

Advertising