One important note, though; Proportional Gain Memory is only

temporary. If you have run one or more bands "past" the +/-12

dB limit and then you exit Edit mode for any reason (such as to

store the program), the gain value of those bands will be

remembered as +/-12 dB (whichever was the value that was last

reached for those bands).

The Limits of Relative Gain

There will be times when the Relative Gain display will not go all

of the way up or down to a value of 24. This is because the

DEQ230 takes into account the gain setting of all of the bands

when an Edit Group is formed. If the highest gain setting of any

band in the Edit Group is + 6 dB, then from there down to -12 dB

is only 18 dB. So this is the largest number you will see in the

Relative Gain display if you run the relative gain value all the way

down (see fig. 3 and 4).