DISPLAY SETUP

- - - - - - - - - - - - - - - - - -

DOME LABEL

OFF

PRESET LABEL OFF

ZOOM LABEL OFF

ZONE LABEL OFF

DIRECTION LABEL

OFF

TEMPERATURE LABEL OFF

TIME LABEL

OFF

DATE LABEL

OFF

BACK

EXIT

MOTION

- - - - - - - - - - - - - - - - - -

AUTO FLIP

OFF

PROPORTION PAN OFF

PARK TIME 000

PARK ACTION NONE

POWER UP ACTION NONE

FAN ENABLED 113

BACK

EXIT

INITIAL INFO
Shows the serial number, current firmware version and other settings.

[BACK]: Move to previous screen

[EXIT]: Exit the OSD

DISPLAY SETUP
Customize the labels shown on the OSD

[DOME LABEL]: Shows dome label name on OSD

[PRESET LABEL]: Shows the current preset label on OSD (see pg.15; “Preset”)

[ZOOM LABEL]: Shows magnification setting on OSD

[ZONE LABEL]: Shows current zone (must first be set up: see pg.17; “Zones”)

[DIRECTION LABEL]: Shows current direction on OSD: Displayed as (Pan: 0º-359º,

Tilt: 0º-90º)

[TEMPERATURE LABEL]: Shows current temperature inside dome on OSD

[TIME LABEL]: Shows current time on OSD. Displayed as Year/Month/Day.

[DATE LABEL]: Shows current date on OSD. Displayed as 24 hour clock.

[BACK]: Move to previous screen (doing so will save your changes to display setup)

[EXIT]: Exit the OSD (doing so will save your changes to display setup)

MOTION
The motion control includes the setting for Park Time action and other features.

[AUTO FLIP]: Disabling this function will limit the tilt range to 90 degrees only

[PROPORTIONAL PAN]: Pan speed adjusts accordingly to the zoom ratio. The more

the operator zooms in, the slower the pan speed. The Park Time speed will be

adjusted accordingly.

[PARK TIME]: Sets the idle time in minutes, until [PARK ACTION] is activated.

[PARK ACTION]: You can select an action that will be started after certain idle time,
such as preset, tour or pattern. Select NONE to disable the function.

[POWER UP ACTION]: Instructs the dome to start a predefined action when
system boots up and completes the self test. This could be helpful to restore the
observation after power loss.

[FAN ENABLED]: Sets the temperature limit for the internal cooling fan to start.

[BACK]: Move to previous screen (doing so will save your changes to motion)

[EXIT]: Exit the OSD (doing so will save your changes to motion)

INITIAL INFO

- - - - - - - - - - - - - - - - - -

S/N: XXXXXXXXXXXXXXX

CLINTON V2.42

PROTOCOL: CLINTON

DOME ADDRESS: 001

COMM 9600, N, 8, 1

BACK

EXIT

DOME LABEL

TEMP

PRESET LABEL

ZONE LABEL

DATE

DIRECTION ZOOM TIME

Advertising