Table 2-1 red dot adjustments – EOTech Mini Red Dot Sight (MRDS) User Manual

Page 19

Advertising
background image

2-5

CAUTION

..

Forcing the boresight adjusters beyond their end of travel may result in
permanent damage to the MRDS.


The adjusters have tactile detents that allow the operator to move the red dot in precise
increments of .29 mrad (1 MOA) per click. The adjusters are turned clockwise or
counterclockwise using a small slotted screwdriver. Markings on the MRDS housing
correspond to shot group movement. In practice, each click translates to moving the point of
impact of the round as follows:

Table 2-1 Red Dot Adjustments

Single Click Equivalents

10m

.30 cm

25m

.73 cm

50m

1.5 cm

100m

2.9 cm


2.5.2 Alignment Procedure for Infinite Parallel

. The procedure below explains how to align the

MRDS to be parallel with the barrel of the host weapon on a 25-meter range. This “infinite
parallel” configuration is appropriate for many mission profiles with engagement ranges out to
approximately 50m. Zeroing the MRDS / weapon combination for greater distances should be
accomplished at an extended range using the procedure described in section 2.5.3.

Advertising