Connections and Wiring

17

NI-700 & NI-900 Hardware Reference Guide

Wiring A Power Connection

To use the 2-pin 3.5 mm mini-Phoenix connector with a 12 VDC-compliant power supply, the incoming
PWR and GND cables from the external source must be connected to their corresponding locations on
connector (FIG. 2).

1.

Insert the PWR and GND wires on the terminal end of the 2-pin 3.5 mm mini-Phoenix cable. Match
the wiring locations of the +/- on both the power supply and the terminal connector.

2.

Tighten the clamp to secure the two wires. Do not tighten the screws excessively; doing so may strip
the threads and damage the connector.

3.

Verify the connection of the 2-pin 3.5 mm mini-Phoenix to the external 12 VDC-compliant power
supply.

Using the 4-pin Mini-Phoenix Connector For Data and Power

Connect the 4-pin 3.5 mm mini-Phoenix (female) captive-wire connector to an external NetLinx device
as shown in FIG. 3.

FIG. 2

2-pin mini-Phoenix connector wiring diagram (direct power)

FIG. 3

Mini-Phoenix connector wiring diagram (direct data and power)

PWR +

GND -

To the Integrated Controller

Power Supply

To the Integrated Controller’s

To the external AXlink device

AXlink/PWR connector

PW

R

+

AXP

/TX

AXM/

R

X

GND -

Top view

Top view

PWR +

A

XP/

TX

AX

M

/R

X

GND -