Connections and Wiring

19

NI-700 & NI-900 Hardware Reference Guide

The table below provides information about the connector pins, signal types, and signal functions.

This table’s wiring specifications are applicable to the rear RS-232/422/485 Device Port connectors on
the: NI-700 (Ports 1 & 2) and NI-900 (Port 1).

IRX-RX Port: Connection and Wiring

The NI-700 and NI-900 units both have a single rear 4-pin IR receiver port (IR RX).

This port can be used to connect one or more (8 maximum in parallel) optional IRX-SM+ or
IRX-DM+ Decora mount IR receivers to the Integrated Controller as shown in FIG. 6.

RS-232/422/485 Device Port Wiring Specifications

Pin Signal Function

RS-232 RS-422

RS-485

1

RX-

Receive data

X

X (strap to pin 9)

2

RXD

Receive data

X

3

TXD

Transmit data

X

4

TX+

Transmit data

X

X (strap to pin 6)

5

GND

Signal ground

X

X

6

RX+

Receive data

X

X (strap to pin 4)

7

RTS

Request to send

X

8

CTS

Clear to send

X

9

TX-

Transmit data

X

X (strap to pin 1)

The IR RX port functions using AMX IR codes (38 KHz and 455 KHz) and works
ONLY with AMX IR Receivers such as the IRX-DM+ and IRX-SM+.

FIG. 6

IR RX port sample connections (AXlink to NetLinx connectors shown)

PWR

GND

IN
AUX

OUT

AUX OUT

+12 VDC

GND

IRX-SM+ #2

IRX-SM+ #1

To the Integrated

Top view

Top view

Top view

OUT

AUX OUT

+12 VDC

GND

Controller’s rear

IR RX connector

Advertising