Connections and Wiring

21

NI-700 & NI-900 Hardware Reference Guide

IR/Serial Port: Connections and Wiring

You can connect only one IR- or Serial-controllable device to the IR/Serial connectors on the rear of the
NI-700 (FIG. 8) but you can connect up to three IR- or Serial-controllable devices to the rear of the
NI-900.

These connectors accept an IR Emitter (CC-NIRC) that mounts onto the device's IR window, or a
mini-plug (CC-NSER) that connects to the device's control jack. You can also connect a data 0 - 5 VDC
device. This unit comes with a single CC-NIRC IR Emitter (FG10-000-11).

The IR/Serial connector wiring specifications are listed in the following table.

Ethernet/RJ-45 Port: Connections and Wiring

The following table lists the pinouts, signals, and pairing for the Ethernet connector.

FIG. 8

IR/SERIAL connectors (male)

IR/Serial Connector Wiring Specifications (per Port)

Number of

IR connections

NI-700

Port #

NI-900

Port #

Signal

Function

1

3

2

GND (-)
Signal 1 (+)

Signal GND
IR/Serial data

2

N/A

3

GND (-)
Signal 2 (+)

Signal GND
IR/Serial data

3

N/A

4

GND (-)
Signal 3 (+)

Signal GND
IR/Serial data

Ethernet RJ-45 Pinouts and Signals

Pin Signals

Connections Pairing Color

1

TX +

1 --------- 1

1 --------- 2 Orange-White

2

TX -

2 --------- 2

Orange

3

RX +

3 --------- 3

3 --------- 6 Green-White

4

no connection

4 --------- 4

Blue

5

no connection

5 --------- 5

Blue-White

6

RX -

6 --------- 6

Green

7

no connection

7 --------- 7

Brown-White

8

no connection

8 --------- 8

Brown

NI-700 IR/Serial connector

configuration (Port 3)

NI-900 IR/Serial connectors

configuration (Ports 2 -4)

1 2 3

4 5 6 7 8

1 2 3

4 5 6 7 8