Fiber clip, Fiber guides, Fiber patch cord – ADC DL3XR-FCA100 User Manual
Page 23
LTPS-UM-8013-03
Installing a D3LX RMT Module in a Remote Cabinet
D3LX CO and RMT Modules
August 30, 2002
15
3
Locate the mounting slots designated for the D3LX RMT modules in the chassis. If protection switching is
required, a working module installs in the first slot of a quad group, such as 1-1 or 2-1. The protection module
installs in the slot to the right of the working module, slot 1-2 or 2-2.
4
Refer to
for D3LX RMT module locations chassis and slot corresponding to the DS3 signal.
–
If no protection switching is required, proceed to the next step.
–
If protection switching is required, a working module may be installed in the first slot of any quad group,
such as 1-1 or 2-1. The protection module is installed in the slot to its immediate right in the order of 1-3
or 2-3. For more information on protection switching, refer to
“Protection Switching” on page 4
Install the working module first, then the protect module.
5
Remove a new module from its protective ESD packaging. If the module is installed, remove it and inspect
for physical damage.
6
Align the module with the slot and slide the module into the chassis until about three inches protrude from
the front of the chassis. Do not seat module in connector at this time.
7
Remove the protective dust cap from the connector on the D3LX RMT module.
Figure 9.
D3LX RMT Module Locations in a Four-Position Remote Terminal Cabinet
8
After removing the protective cover from a fiber patch cord, confirm that the fiber-optic connector is free of
debris as directed in
“Appendix B - Cleaning and Mating Fiber-Optic Systems” on page 39
.
9
Proceed to
“Power Verification” on page 16
D3LX RMT modules
D3LX LTU
jack block
Fiber clip
Fiber
management
enclosure
POWER
AC/DC
POWER
AC/DC
CR
MJ
MN
ACO
PWR
HSKP
RMT
ALM
LMPTST
DISP RMT
STATUS
APS/LMP TST
D3LX RMT
OPT
APS
STATUS
FAR END
DS3 STATUS
DS3 ONLINE
LMPTST/
APS
RESET
ENABLE
FAIL
BER
LOCKOUT
FORCE
R=FAULT
G=O.K.
FLASH=LBK
OFF=UNEQPP
G=ONLINE
OFF=OFFLINE
A
P
U
STATUS
FAR END
DS3 STATUS
DS3 ONLINE
LMPTST/
APS
RESET
ENABLE
R=FAULT
G=O.K.
FLASH=LBK
OFF=UNEQPP
G=ONLINE
OFF=OFFLINE
D3LX RMT
OPT
APS
STATUS
FAR END
DS3 STATUS
DS3 ONLINE
LMPTST/
APS
RESET
ENABLE
FAIL
BER
LOCKOUT
FORCE
R=FAULT
G=O.K.
FLASH=LBK
OFF=UNEQPP
G=ONLINE
R=LINELOCK
OFF=OFFLINE
D3LX RMT
OPT
APS
STATUS
FAR END
DS3 STATUS
DS3 ONLINE
LMPTST/
APS
RESET
ENABLE
FAIL
BER
LOCKOUT
FORCE
R=FAULT
G=O.K.
FLASH=LBK
OFF=UNEQPP
G=ONLINE
R=LINELOCK
OFF=OFFLINE
Fiber clip
TX
RX
1-1
2-1
1-3
2-3
TX
RX
TX
RX
TX
RX
Fiber guides
2-1
2-3
1-3
1-1
Fiber patch cord
D3RCAM
APU
D3LX RMT
DS3 CAM
ENABLE
APS
NET
OPT
APS
FAIL
BER
LOCKOUT
FORCE
CRAFT
EOP
FAIL
ERROR
FAIL
ERROR
STATUS
D3RCAM
RESET
C
R
A
F
T