ADC DL3XR-FCA100 User Manual

Page 32

Advertising
background image

Local Configuration

LTPS-UM-8013-03

24

August 30, 2002

D3LX CO and RMT Modules

4

Configure the fields as detailed in the

Table 5

and assign the selections by pressing

.

5

Repeat Steps 2 through 5 for each D3LX system installed in the chassis.

Press

+

for assistance when making selections.

Table 5.

D3LX CO Configuration Fields–SCU V3.7 or later

Field Name

Type

Options

Description

Default

Unit Equip State

Toggle

EQUIPPED

Establishes communication with SCU. Module
must be set to EQUIPPED before remaining
selections are allowed.

UNEQUIPPED

UNEQUIPPED

No communication with SCU.

Unit Service State

Toggle

IN SERVICE

Places the unit in service and allows equipment
alarm reporting by the SCU. Must be set to IS
for reporting of equipment alarms.

OOS

OUT OF SERVICE

Removes unit from service and stops
equipment alarm reporting by the SCU.

Unit Protect State

Toggle

PROTECTED

Line protection

Unprotected

UNPROTECTED

No protection

Optical Service State

Toggle

IN SERVICE

Places facility in service and enables T2 alarm
reporting by the D3LX CO.

OOS

OUT OF SERVICE

Removes facility from service and stops T2
alarm reporting by the D3LX CO.

Optical BER Alarm
Threshold

Toggle

Set to OFF or set
between 10

-6

and 10

-10

The average Bit Error Ratios of both the
incoming optical signals are monitored by the
D3LX CO. By monitoring BERs, the D3LX CO is
capable of triggering a minor alarm when any of
the monitored signals degrades below the BER
threshold level.

10

-8

Optical BER Switch
Threshold

Toggle

Range from 10

-4

to

10

-10

Sets the threshold at which the APS will be
executed.

10

-6

DS3 Provisioned

(set for each T1)

Toggle

YES

Brings up T1 default settings and allows
configuration changes.

NO

NO

No configuration changes allowed.

DS3 Service State

Toggle

IN SERVICE

Select IS after completing the remaining con-
figurations.

OOS

OUT OF SERVICE

Leave this field at OUT OF SERVICE (versus IN
SERVICE) at this time to avoid undesirable
reporting of alarms.

DS3 Transmit LBO
Local

Toggle

0–225 ft., 226–450 ft.

The DS1 signal output provides standard DSX
signal levels which can be compensated for at
various distances, such as cable length.

0–225 ft.

DS3 Transmit LBO
Remote

Toggle

0–225 ft., 226–450 ft.

The DS1 signal output provides standard DSX
signal levels which can be compensated for at
various distances, such as cable length.

0–225 ft.

Continued

CTRL

A

ENTER