Maintenance

70400401

20

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Daily Maintenance

Monthly Maintenance

To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be

reconnected to ensure that the tumbler is properly grounded.

W002

WARNING

Inspect the area surrounding tumblers,
remove all combustible materials,
including lint, before operating the
machine.

Check cylinder for foreign objects to
avoid damage to clothing and
equipment.

Clean lint from lint compartment and
screen to maintain proper airflow and
avoid overheating.

Remove lint and debris from inside
exhaust duct to maintain proper airflow
and avoid overheating.

Ensure even lint distribution over lint
screen, replace if distribution of lint is
uneven to maintain proper airflow and
avoid overheating.

Carefully wipe any accumulated lint off
the cabinet high limit thermostat and
thermistor, including perforated cover.
Lint buildup will act as an insulator,
causing machine to overheat.

Clean lint and debris buildup from
blower to maintain proper airflow, to
avoid overheating and prevent possible
vibration.