Warning – Alliance Laundry Systems Drying Tumbler Part No. 70400401R2 User Manual

Page 23

Advertising
background image

Maintenance

21

70400401

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Quarterly Maintenance

Bi-Annually Maintenance

Use a vacuum to clean air vents on
drive motors.

Use a vacuum to clean lint from rear
limit thermostat cover.

Check and clean steam coils.

Check flow of combustion and
ventilation air.

Check belt tension and condition.
Replace worn or cracked belts.

WARNING

To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be

reconnected to ensure that the tumbler is properly grounded.

W002

Check mounting hardware for any
loose nuts, bolts or screws.

Check gas connections for leakage.

Check for loose electrical connections.

Check steam connections for looseness
and leakage.

Remove all front panels and vacuum,
including coin drop mechanisms.

Check cylinder and front panel seals.

Inspect cabinet and inner panels for any
damage, replace or repair as needed.

Clean burner tubes of any lint buildup.

Advertising