APW Wyott VSX User Manual

Page 9

Advertising
background image

'

Problem

Possible Cause

Corrective Action

Crown and / or heel must

be forced into the toaster.

Toaster is overheating or

cooling fan is not turning

properly.

Toaster making noise or

conveyors are squeaking.

(Note that some noise is

inherent to the normal

operation of the toaster &

does not require Field

Service. If unsure, call

the APW Wyott technical

service department.)

Temperature Control

Display Error Code – High

Temperature (rly)

Temperature Control

Display Error Code – Probe

or Sensor (prb)

No Temperature Control

Display, or erratic display,

or displays ’---‘

Release Sheet and / or Silicone Belt need

cleaning.

Bun Chute improperly installed.

Dirt and build-up on the Fan Blades or in

the Fan Motor.

Drop down Side Panels rattle.

Lid Rattles

Chains emit squeaking or skipping noise or

any noise indicating metal is rubbing on

metal.

Belt Wrap Pin rubbing on metal housing.

Silicone Belt wrap is installed incorrectly.

Failed Solid-state Relay, Heating Platen, or

Temperature Control Board.

Loose or “open” Sensor, failed Sensor.

Unit not plugged in.
Circuit Breakers turned off or tripped.

Wire problem, failed Circuit Board, or

damaged Electrical Components

Cooling Fan not turning properly. Control

compartment temperature is above 150° F.

Clean or replace Release Sheet or Silicone Belt according to

The instructions in this manual.

Review installation instructions and relocate Bun Chute.

Verify that the bottom of the Bun Chute is level and setting flat

on the counter or table.

Turn the unit off, disconnect from power, allow to cool, and

clean the Cooling Fan Blades.

Verify that the Door is undamaged, closed and properly seated

on the top cross rods. Verify the Silicone Belt is properly installed.

Verify the Lid is undamaged, and re-secure it to the top

of the toaster.

Center the pin in the Belt Wrap Zipper.

Re-install the Silicone Belt according to the instructions in this

manual.

Contact an authorized APW service technician.

Contact an authorized APW service technician.

Plug unit into proper electrical outlet .
Reset Breakers. If they trip again, contact your local electrician

or authorized APW service technician.

Contact an authorized APW service technician.

Turn unit off, disconnect power, allow to cool, clean Cooling Fan.

technician.

service

Manual Reset Thermostat

The manual reset is a device that provides thermal protection for the platen. In the event that the main

controller or power relay fails to regulate the heat on the platen, the manual reset thermostat will break the

electrical connection to the platen. The control, the motors, the conveyors, and the fans may all continue to

operate, but no more heat will go to the platen. The manual reset thermostat will prevent any power from

going to the platen until a person resets it.

If the manual reset thermostat trips (disallows heat to the platen), this may indicate an extreme failure of

another device. If this thermostat trips more than once, it is important that you contact an authorized APW

Wyott technical service technician.

To reset the thermostat, locate the thermostat at the rear of the toaster. There is a black knob near the power

cord and the rating label. Unscrew the black cover (you may need a screwdriver). Push in the button that it

is covering. Replace the black cover (hand tight).

If the noise is minor squeaking, this is normal for the toaster &

will not cause a problem. To eliminate the noise, lubricate weekly

with a high temperature, food-grade lubricant (e.g. Sprayon

210LQ, see www.sprayon.com). DO NOT use a vegetable based

cooking spray. If the noise is a scraping noise, it may be possible

that the pin for the belt splice is coming out & scraping against

the toaster. Merely push the pin back into the belt splice. If none

of these correct the problem, & the toaster persists in making a

loud noise, please contact an authorized APW technical service

technician.

Advertising