Rs-232c interface, Command format, Rs-232c specifi cations – Anthem LTX 300 User Manual

Page 50

Advertising
background image

6

Others

50

RS-232C Interface

Control of this unit via a computer is possible by connecting the computer to this unit with a RS-232C
cross cable (D-Sub 9 pin).









PC refers to the controller such as a personal computer.

D6 D7

D4 D5

D2 D3

D0 D1

Command Format

The command between this unit and the computer consists of Header , Unit ID , Command , Data and End .

Header (1 byte), Unit ID (2 bytes), Command (2 bytes), Data (n bytes), End (1 byte)

Header

This binary code indicates the start of communication.

Binary code

Type

Description

21

Operating command

PC→This unit

3F

Reference command

PC→This unit

40

Response command

This unit→PC

06

ACK

This unit→PC
(When the command is accepted without error, it returns to
PC)

Unit ID

This code specifi es the unit. The binary code is fi xed at 8901 .

RS-232C Specifi cations

Pin No.

Signal

Function

Signal Direction

2

RxD

Receive data

PC→This unit

3

TxD

Transmit data

This unit→PC

5

GND

Signal ground

-

1,4,6 - 9

N/C

-

-

Mode

Non-synchronous

Character Length

8 bit

Parity

None

Start Bit

1

Stop Bit

1

Data rate

19200 bps

Data format

Binary

T

his unit

Start Bit

Stop Bit

Advertising