Rs-232c communication examples – Anthem LTX 300 User Manual

Page 53

Advertising
background image

ENGLISH

53

Getting Started

Preparation

Basic Operation

Troubleshooting

Settings

Others

RS-232C Communication Examples

This section shows the communication examples of RS-232C.

Operating command

Type

Command

Description

Connection check

PC→This unit: 21 89 01 00 00 0A
This unit→PC: 06 89 01 00 00 0A

Connection check

Power (On)

PC→This unit: 21 89 01 50 57 31 0A
This unit→PC: 06 89 01 50 57 0A

When power is turned on from standby
mode

Power (Off)

PC→This unit: 21 89 01 50 57 30 0A
This unit→PC: 06 89 01 50 57 0A

When power is turned off (standby mode)
from power-on mode

Input (COMP.)

PC→This unit: 21 89 01 49 50 32 0A
This unit→PC: 06 89 01 49 50 0A

When video input is set to component

Remote Control

(MENU)

PC→This unit: 21 89 01 52 43 37 33 32 45 0A
This unit→PC: 06 89 01 52 43 0A

When the same operation as pressing
the [MENU] button on the remote control
is made

Reference command

Type

Command

Description

Power (On)

PC→This unit: 3F 89 01 50 57 0A
This unit→PC: 06 89 01 50 57 0A
This unit→PC: 40 89 01 50 57 31 0A

When information of power-on mode is
acquired

Input (S-VIDEO)

PC→This unit: 3F 89 01 49 50 0A
This unit→PC: 06 89 01 49 50 0A
This unit→PC: 40 89 01 49 50 30 0A

When information of S-VIDEO input is
acquired

Advertising