6. Sample Rate


Enter SETUP and select the new sample rate by pressing the
respective button.

Button -0.1% will apply a so-called pull down sample rate
(x1000/1001) as used for video and film post-productions for NTSC
frame rate compensation.

Do not use pull down rates for standard audio applications.

Sample rate buttons are blinking when the unit is relocking/
synchronising to a new reference or sample rate.

When stable LOCK is achieved the sample rate buttons light up
continuously.


7. Output Mode



Enter SETUP and press the MODE button to change the output
mode of outputs 1..12.

By pressing buttons 1..12 you can select output modes:

green: WORD CLOCK

red:

AES11 DARS digital audio refrence signal

off:

USER, in firmware version 1: output muted

with the nanoclocksGL setup software you can

configure each output individually for x2, x4, SPDIF
and other output modes, coming later with firmware 2


Press and hold the SAVE button for three seconds to store new
settings to non-volatile memory.