- 7 -



Correct termination is quite important to avoid cable reflections,
especially for the higher frequency AES11 signals.

The nanoclocks GL is monitoring the connection status on each
output and displays the present state of termination.

(1) Press the STATUS key.

(2) buttons 1..12 for outputs 1..12 will display:

off:

output is open or not terminated, > 85

green: output is in use and terminated with 75

red:

output is double/ low terminated, < 50




4. System Settings


Each of the three system buttons SETUP, SAVE and "on/off" must
be pressed and hold for three seconds to enter setup mode, save the
current settings or to enter power down mode.

If you press these buttons shortly or unwittingly, there will be no
action.

In SAVE mode you can still use STATUS or MODE buttons to select
the desired display mode.

For all other settings you must enter SETUP mode first:
Press and hold the SETUP button for 3 seconds.

Press and hold the SAVE button for three seconds to store new
settings to nanoclocks GL non-volatile memory.

Press and hold "on/off" key for three seconds to enter power down
mode. All clock outputs will be muted.