Connecting the Components

All controllers ship with Clik™ together wiring harnesses. This eliminates field wiring and
splicing. Use the wiring diagrams below for connecting your solar light system. Note:
includes a field replaceable fuse.

Connect the wiring harness to the battery (or batteries) as shown in Figure 15 (for one or
two batteries), Figure 16 (for three or four batteries), or Figure 17 (for systems with two
luminaires with one, two, three or four batteries).

Battery 1

+

-

Battery 2

(if provided)

+

-

Controller

PV Module

Black (+)

Orange (-)

Black (-)

Red (+)

Green -

Ground

LED Luminaire

Brown (+)

Blue (-)

Luminaire Load Cable

Battery Harness (one per battery)

Harness(single or double)

Battery 1

+

-

Battery 2

+

-

Battery Wiring for

24VDC Systems

Black (-)

Red (+)

FIGURE 15

ONE LED LUMINAIRE WITH 1 or 2 BATTERIES