Calibrating your sprayer – Ag Spray Equipment TR300E User Manual

Page 3

Advertising
background image

CALIBRATING YOUR SPRAYER

HAMILTON NOZZLE 654201

CALIBRATING YOUR SPRAYER

To determine pressure & GPA with a boomless nozzle use this calibration for it is different than a boom calibration:

EXAMPLE:

Refer to Chart

OPERATING DATA OF 180* NOZZLES

SPRAYERS ARE SUPPLIED w/ #10

Orfice

GPM

Swath

GALLON PER ACRE

Number PSI

180*

180*

3 MPH

4 MPH

5 MPH

8 MPH

10 MPH

30

1.7

44'

6.4

4.8

3.8

2.4

1.9

#5

40

2.0

46'

7.2

5.4

4.3

2.7

2.2

50

2.2

48'

7.6

5.7

4.5

2.9

2.3

60

2.4

50'

7.9

5.9

4.8

3.0

2.4

30

3.7

50'

12.2

9.2

7.3

4.6

3.7

#10

40

4.2

50'

13.9

10.4

8.3

5.2

4.2

50

4.6

52'

14.6

10.9

8.8

5.5

4.4

60

5.0

52'

15.8

11.9

9.5

5.9

4.8

30

5.1

54'

15.6

11.6

9.3

5.8

4.7

#20

40

5.9

54'

18.0

13.5

10.8

6.8

5.4

50

6.7

56'

19.7

14.8

11.8

7.4

5.9

60

7.1

58'

20.2

15.1

12.1

7.6

6.1

GPM

=

Gallons Per Minute

GPA

=

Gallons Per Acre

MPH

=

Miles Per Hour

PSI

=

Pressure Per Square Inch

GPA =

495 x GPM

MPH x Swath in feet

495 (constant) x 4.2gpm

4mph x 50ft swath

=

2079

200

=

10.395 GPA

Advertising