TEEJET SPRAY TIP CALIBRATION

For 8 Row Boom

Standard boom comes W/8003VP poly tips.

Formula:

GPA x MPH x Nozzle Spacing
5940

Example:

20gpa x 4mph x 20”

= 1600 = .27gpm

5940

5940

Take the GPM that you figured & look down the GPM chart to figure what pressure you need to run at that
desired speed.

*NOTE: If spraying liquid nitrogen you will need to multiply the conversion factor w/ the gpa, mph, &
nozzle spacing.

Conversion Factor:

28% Nitrogen - 10.65 lbs. per gal. - 1.13
32% Nitrogen - 11.00 lbs. per gal. - 1.15

Example:

20gpa x 4mph x 20” x 1.13 = 1808 = .31gpm

5940

5940