Servicing should only be performed by a Qualified Service Technician

FAULT CONDITIONS

The water heater is equipped with an ignition control that incorporates a diagnostic system to assist in

troubleshooting the appliance. The indicator codes on the ignition module are as follows:

LED INDICATION

FAULT MODE

2 Flashes

Flame sensed without call for heat.

3 Flashes

Ignition Lockout.

Steady On

Internal Control Failure

The LED will flash on for 1/4 second, then off for 1/4 second during a fault condition. The pause between

fault codes is 3 seconds.

INTERNAL CONTROL FAILURE

If the ignition control detects an error in its software or hardware, all outputs are turned off and the LED

displays a steady ON condition. If an internal control failure is indicated, replace the ignition control.

TROUBLESHOOTING GUIDE FOR IGNITION CONTROL

SYMPTOMS

CAUSES

1. Control does not start

a. Miswired.

b. No 24V AC power supply at TH/W terminal.

c. Bad control, check LED for steady on or flashing

code (see above Table).

2. Thermostat on -no spark

a. Miswired.

b. No 24V AC power supply at TH/W terminal.

c. Bad control, check LED for steady on or flashing

codes.

3. Valve on - no spark during TFI

a. Shorted electrode -establish 1/8 inch gap.

b. Check high voltage cable.

c. Miswired.

4. Spark on - valve off

a. Valve coil open.

b. Valve wire disconnected.

c. Bad control, check voltage at gas valve terminals

PV1 and V2.

5. Flame okay during TFI - no flame sense after TFI a. Poor ground at burner.

b. Poor flame, check flame current.

c. Check flame rod position.

FLAME SENSOR CURRENT CHECK

Flame current is the current that passes through the flame from the sensor to ground. The minimum

flame current necessary to keep the system from lockout is 0.7 micro amps. To measure flame current,

connect analog DC microammeter to the FC-, FC+ terminals on the Ignition Control. Meter should read 0.7

microamps or higher. If the meter reads below "0" on scale, meter leads are reversed; disconnect power

and reconnect meter leads for proper polarity.