Default factory DIP Switch setting:

SW1 – RAID Setting DIP Switch

BZS – Error buzzer function

EZ – Automatic rebuilding to spare drive (one of the drives on the raid is set as a

spare). If EZ is ENABLED anda drive failure occurs, the spare will automatically

act as a drive replacement and rebuilding will automatically start.

M2 – RAID mode 2

M1 – RAID mode 1

M0 – RAID mode 0

1.

Error buzzer function is ENABLED (BZS) when dip switch is in OFF position

2.

Auto-rebuilding to spare drive is DISABLED (EZ)

3.

Individual drive mode is ENABLED (M0~M2)

1 2 3 4 5

SW1

BZS EZ M2 M1 M0

OFF

OFF

OFF

OFF

OFF

J3

J1

Error LED

Activity LED

P4 P3 P2 P1 P0 P5

P4 P3 P2 P1 P0 P5

Note: When the default factory RAID setting is used, independent drive configuration

and optical drive are supported only when connecting to controllers with Silicon Image

Sil3124, Sil3132 chip set or controllers that are Port Multiplier (PM) compatible.

Simultaneous DVD writing was tested using the Nero Burning Rom.

LED Pin Header

J1 – Drive Activity LED

P5 – Activity LED for eSATA host port lights up when it is connected to a SATA

controller card.

P0, P1, P2, P3 & P4 - Activity LEDs for port 0, 1, 2, 3, 4 & 5 light up when a drive is

connected and blinks when there’s drive activity.

J3 – Error LED

P5 – error LED for eSATA host port

P0, P1, P2, P3 & P4 - error LED for port 0, 1, 2, 3, 4 & 5