Cable connections, Raid 0 mode, Clone mode – Addonics Technologies RAID RACK RR2035ASDES User Manual

Page 8: Raid 1& raid 10 mode, Large mode, Raid 3 mode, Individual drives mode, Raid 5 mode

Advertising
background image

www.addonics.com

Technical Support (M-F 8:30am - 6:00pm PST)

Phone: 408-453-6212

Email: www.addonics.com/support/query/

Cable Connections

1.

Attach the SATA hard drives (up to 5) to the SATA ports on the Hardware

Port Multiplier (HPM) using SATA cables. It is recommended to connect

drives to the SATA ports 1 to 5 successively.

2.

To provide power to the HPM, connect a 4-pin floppy power cable from the

system power supply to the floppy power connector on the HPM.

3.

Optional: Connect LEDs to the Activity & Error LED jumper block

Setting or Modifying the RAID Mode Using the JMicron

HW RAID Manager Utility Program:

1.

For Windows users, install the JMicron HW RAID Manager located on the

SATA Controller CD. In the CD, go to Configuration Utilities > JMB393. This

manager can be use to create and monitor the status of the RAID volume.

It is recommended to use the default factory RAID DIP switch setting when

using the JMicron HW RAID Manager.

2.

Modify the RAID mode on the 5-port HPM-XA using DIP switch

Recommended to be used on operating system without JMicron HW RAID

Manager support like Linux, Mac & Solaris. Windows users can also use the

procedure below.

Note: Steps A to D need to be performed each time the raid mode is modified.

a.

Set the DIP switch as shown below.

b.

Press the RAID setting button with a ball point pen.

c.

While pressing the RAID setting button turn on the system power

where the HPM is connected. The buzzer will sound while holding the

RAID setting button. Release it after at least 5 seconds for hardware

initialization. A single beep will be heard to indicate initialization is

completed. The above steps act as a reset.

d.

Power off the system power.

e.

On the DIP switch, change (M0 to M2) setting to the

desired RAID mode using the diagram below.

All settings on the diagram shows

Error buzzer function is ENABLED

EZ function is DISABLED.

1 2 3 4 5

SW1

BZS EZ M2 M1 M0

RAID 0 Mode

1 2 3 4 5

SW1

BZS EZ M2 M1 M0

Clone Mode

1 2 3 4 5

SW1

BZS EZ M2 M1 M0

RAID 1& RAID 10 Mode

1 2 3 4 5

SW1

BZS EZ M2 M1 M0

Large Mode

1 2 3 4 5

SW1

BZS EZ M2 M1 M0

RAID 3 Mode

1 2 3 4 5

SW1

BZS EZ M2 M1 M0

Individual Drives Mode

1 2 3 4 5

SW1

BZS EZ M2 M1 M0

RAID 5 Mode

OFF

OFF

ON

ON

ON

OFF

OFF

ON

ON

OFF

OFF

OFF

ON

OFF

OFF

OFF

OFF

OFF

ON

OFF

OFF

OFF

OFF

ON

ON

OFF

OFF

ON

OFF

ON

OFF

OFF

OFF

OFF

OFF

Advertising