Full-scale connectivity

Standard USB, Ethernet/LAN and
GPIB interfaces – choose the interface
you want to use
The 6000 Series scopes come
with standard USB 2.0 USBTMC
device, 10/100 Mbps LAN and
GPIB interfaces on the rear panel
and USB 1.1 host interfaces on
the front and rear panels.

• USB offers the quickest and

easiest connection scheme –
it’s perfect for benchtop use
and systems connection.

• LAN offers high-speed

connectivity over longer
distances and allows sharing
of instruments among
multiple PCs.

• GPIB has many years of proven

reliability for instrument
communication – a good choice
for use in existing GPIB-based
test systems.

Front-panel USB port
A built-in front-panel USB port
makes it easy for you to store
waveform data, screen images,
and scope setups to a USB
flash drive. You can store your
waveform images as BMP or PNG
files and your waveform data as
CSV, ASCII XY pair and binary
format files for easy import into
other PC applications. If you
share your lab equipment with
others, you can save your
measurement setups and traces
to your own USB flash drive,
making it simple to save and share
your every-day setups as well as
your advanced configurations.

Built-in XGA video output
allows you to connect to a large
external monitor or project your
screen image to a large wall screen
in classroom environments.

Free IntuiLink Data Capture software
simplifies PC connectivity
When you need to transfer images
and waveform data to your PC,
IntuiLink Data Capture lets you
focus more time on design issues
rather than on programming.
With the click of a button on the
Data Capture’s dialog box, you
can download data or transfer
a snapshot of an oscilloscope
bitmap screen directly to your
PC, or save the image as a bitmap
file. For more information on
IntuiLink Data Capture, visit
www.agilent.com/find/intuilink.

IVI-COM driver
For a higher-level of instrument
control, use the IVI-COM driver
for the 6000 Series in your
application. Download the
IVI-COM driver for 6000
Series free from the Agilent
Developer’s Network at
www.agilent.com/find/adn.

Logic analyzer and oscilloscope
correlation
Easily make time-correlated
measurements between an
Agilent 1680, 1690 or 16900
Series logic analyzer and a
6000 Series oscilloscope. The
time-correlated logic analyzer
and 6000 Series oscilloscope
waveforms are integrated into a
single logic analyzer waveform
display for easy viewing and
analysis. You can also trigger
the 6000 Series oscilloscope
from the logic analyzer (or vice
versa), automatically de-skew
the waveforms and maintain
marker tracking between the
two instruments.

Figure 7. A built-in USB port makes it
easy to save and share your work and
update your system software quickly.

Figure 8. Agilent 6000 Series with an
external monitor attached.

Figure 9. Make time-correlated
measurements between an Agilent logic
analyzer and 6000 Series oscilloscope.

Advertising