Standard objects – AMETEK 1990 DN DeviceNet Resolver Interface Module User Manual

Page 9

Advertising
background image

9

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.AMETEKAPT.com

4.2: Standard Objects

4.2.1: Identity Object (Class ID = 1)

Attribute ID

Access Rule

Name

Data Type

Value

1

Get

Vendor

UNIT

0x009C

2

Get

Product Type

UINT

0x0000

3

Get

Product Cod

UINT

0x07C2

4

Get

Revision

STRUCT

01.00

5

Get

Status

WORD

0x0000

6

Get

Serial #

UDINT

0x00000001

7

Get

Product Name

STRUCT

15, “1986DN Resolver”

4.2.2: Message Router Object (Class ID = 2)

There is no externally visible interface to the Message Router Object.

4.2.3: DeviceNet Object (Class ID = 3)

There is a single instance of the DeviceNet Object for the DeviceNet Resolver. No class attributes are

supported.

Attribute ID

Access Rule

Name

Data Type

Value

1

Get/Set

MACID

USINT

0x63

2

Get/Set

Baud Rate

USINT

125K

3

Get/Set

BOI

BOOL

0x00 Hold in Reset

4

Get/Set

Bus-off Counter

USINT

0x00

5

Get

Allocation Information

STRUCT

Allocate Service

4.2.4: Connection Object (Class ID = 5)

There are three instances of the connection object. Instance #1 is assigned to the explicit messaging

connection. Instance #2 is assigned to the Polled I/O connection. Instance #3 is assigned to the bit-strobe

I/O connection.