Mvp-r, Ramping controller – High Country Tek MVP-R Series User Manual

Page 11

Advertising
background image

021-MVP-R Rev A

MVP-R User Manual

11

Copyright © High Country Tek, Inc.

– 2013

MVP-R

Ramping Controller

MVP-RPx-xxx - The title parameter is fixed. It displays the model number and the firmware version.

RAMP TIME FACTOR

Sets the rate of change for the output current. If the Ramp Time Factor is x1, the ramp

time will match the ramp time settings. If it is set to 1/10, the ramp time will be 1/10 of the ramp time setting.

RAMP UP/DOWN TIME - Sets the rate of change for Output current.

For RP1, the output current increases from Minimum to Maximum.

For RP2, the output current is initially set to the Minimum.

The output current increases from Minimum to Maximum within the Ramp Up time when switching ON
“ENABLE” switch.

The output current decreases from Maximum to Minimum within the Ramp Down time when switching
OFF “ENABLE” switch.

MIN OUTPUT - Sets the minimum output current (milliamps, amps for -12A,-25A). The value in the brackets is the

present output current.

MAX OUTPUT - Sets the maximum output current (milliamps, amps for -12A,-25A). The value in the brackets is the

present output current.

DITHER FREQ.

Options: 80, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280, 300, (Select OFF for 1000Hz).

Set the PWM or dither frequency according to the valve specifications. This parameter is variable.

OUTPUT CURRENT - Displays the present output current. This parameter is a monitor type.

SUPPLY VOLTAGE - Displays the

module’s power supply voltage. It is helpful for troubleshooting. This parameter

is a monitor type.

FAULT STATUS - The STATUS LED will flash red 2 times for Coil Open and 3 times for Coil Short.