DRC

Valve Controller

Parameter List

The following table outlines the DRC parameters as well as the limits and units of measure for each parameter.

Parameter

Limits

Units

DRCx-xxx

Version #

C1 Mode

See Mode Description

Mode #

C1 Min input

-10 to +10.0

4 to 20.0

V

mA

C1 Max input

-10 to +10.0

4 to 20.0

V

mA

C1 Min output

0 to 600

1

mA

C1 Max output

0 to 600

1

mA

C1 Ramp up

0.0 to 120.0

Seconds

C1 Ramp down

0.0 to 120.0

Seconds

Previous 7 parameters repeated for all channels2

Dither frequency

30 to 1000

Hz.

C1 Command input

V (mA)

C1 Output current

mA

Previous 2 parameters repeated for all channels2

Supply voltage

Volts

Fault status

Fault

1

0 to 120 mA for

–01A version, 0 to 1.2 A for –12A version, 0 to 2.5 A for –25A version

2

Parameters starting with C1 are repeated for each channel and are displayed as C2 to C4