Application examples, Open loop single solenoid control (drc1-vxx), Drc1 – High Country Tek DRC Series User Manual

Page 16: Valve controller

Advertising
background image

021-DRC Rev A

DRC User Manual

16

Copyright © High Country Tek, Inc.

– 2013

DRC

Valve Controller

Application Examples

Open Loop Single Solenoid Control (DRC1-Vxx)

The DRC can drive a single solenoid with a joystick or
potentiometer of

10kΩ.

Mode 1 is used when the enable switch is not used.
Mode 2 is used when the enable switch is used.

The command input can be inverted.

Set the dither and output settings according to the valve
specifications.

Example Settings

Parameter

Value

C1 Mode

2 IN1 USE ENBL

C1 Min input

0.2 V

C1 Max input

10.0 V

C1 Min output

5 mA

C1 Max output

600 mA

C1 Ramp up

1 S

C1 Ramp down

1 S

Dither frequency

150 Hz.

Schematic

FUSE

+V Power Input
9 - 32VDC

+V = Enabled

PWR J1-1

DRC1

Electronic Valve

Controller

Enable J1-3

GND J1-2

-10V Ref. Out J4-1

+10VDC @ 20mA

0-10VDC

+10V Ref. Out J4-3

Ch. 1 I/P J5-1

Sig GND J4-2

J5-2

V

D

C

I/

P

m

A

I/

P

Supply Voltage

4-20mA

Ch. 2 I/P J5-3

Prop. PWM (Sourcing)

Sig GND J2-2

Ch. 2 Out J2-3

Ch. 1 Out J2-1

Input / Output Diagram

Command

Input

0.2V

10V

5mA

600mA

Output Current

Advertising