Technical data

Power connection (voltage/frequency)

220-240 V / 50-60 Hz

Heater wattage

1600 W

Maximum static pump pressure

15 bar

Maximum water tank capacity (without filter)

1.7 liters

Maximum capacity of the coffee bean container

300 grams

Length of power cable

100 cm

Dimensions (H x W x D)

385 x 280 x 479 mm

Weight, empty

9.3 kg

Type of grinding unit

Ceramic

Problem

Cause

Solution

Display shows

Insert brewing unit

Brewing unit (5) is missing

or was not recognised.

Switch off the appliance with

the brewing unit (5) in place,

wait three seconds and

switch on the appliance.

Restore the unit to its

original factory settings

(“Reset”).

You changed some settings

and want to discard them.

Turn off the unit with the

power on/off switch

O / I (9).

Press and hold the

e

off /

j

(12) and the

h

(11) button

and turn the appliance on

with the power on/off switch

O / I (9). Conirm by pressing

the start button

start (10).

The factory settings are now

activated.

If you are unable to solve the problem, please call the hotline.