Technical specification, Resetting to factory defaults, Flash information display – Phottix Mitros for Nikon User Manual

Page 15: Changes to the flash capacitor

Advertising
background image

15

En

INSTRUCTION MANUAL

Technical Specification

Modes: TTL, Manual, and Multi Stroboscopic
Guide No.:
58/190 (at 105mm focal length, ISO 100 in meters/feet)
Flash coverage: 17-105mm (14mm with wide angle diffuser panel)
Auto zoom (Flash coverage automatically adjusts to match the lens focal

length)
Manual zoom (Zoom can be adjusted by changing setting on the flash/camera)
Rotation: 360 degrees, Up-Down: -7 to 90 degrees
FEC (Flash exposure compensation): Manual
Sync modes: First Curtain Sync, Second Curtain Sync, and High Speed Sync
Stroboscopic flash: Frequency: 1-100 Hz Number of flashes: 1- 90
Flash exposure confirmation: Blue LED lamp lights up in TTL mode
Flash Recycling (with size-AA alkaline batteries)
Recycling time/Flash-ready indicator:
Normal flash: Approx.0.1-5 sec./Red LED indicator lamp lights up.
Quick flash: Approx.0.1-2.5 sec./Green LED indicator lamp lights up.
Internal power: Four size-AA alkaline batteries or size-AA Ni-MH batteries
External battery: Compatible with Phottix Battery Pack and Nikon High-Per-

formance Battery Pack SD-9 through specific adapter
Power saving: Non-wireless Slave modes: 90 seconds, Wireless Slave mode:

(programmable) 10 minutes or 60 minutes
Wireless flash
Transmission method:
Radio Frequency and Optical pulse
Channels: 4
Wireless options: Odin Tx, Odin Rx, Strato II Rx, OP Tx (Master), OP Rx (Slave),

OP Slave, OFF
Transmission range (Approx.): Radio: 100m +, Optical: Indoors: 12-16m/39.3-

52.4 ft., Outdoors: 7-9m/22.9-29.5 ft.
Reception angle: Radio: 360 ° all directions, Optical transmission:±40°(hori-

zontal), ±30°(vertical)
Controlled Slave groups:
3 (A, B, and C)
Standby current: ≤100uA in sleep mode
Dimensions: (L x W x H): 202.8Ч77.5Ч58.3 mm
Weight: 425.7g (flash only, excluding batteries)

Resetting to Factory Defaults

The Phottix Mitros+ Flash can reset to factory defaults.

To reset the flash:

1. Press and hold the

and buttons for 3 seconds.

2. The flash will reset to factory default settings.
3. All custom functions will be reset to factory defaults.

Flash Information Display

For technical support or firmware upgrade checking the Phottix Mitros+ infor-

mation may be need. To display the hardware, software, icon library and serial

number display:

1. Press the

button as the flash is turned on.

2. Press any button to cancel this display and enter the LCD screen.

Changes to the flash capacitor:

If the flash is not used for some time physical changes will take place within the

flash’s capacitor. Make sure to turn on the flash a minimum of 10 minutes every

three months to prevent any physical changes.

Advertising