FRONT PANEL:

(refer to Figure 2)

Pressure Gauge: Measures outlet pressure of high pressure pump in pounds per square inch (psi).

Ammeter: Allows precise adjustment of the pump outlet pressure without overloading the pump mo-
tor. Proper adjustment for maximum pressure is at the break line between green and yellow.

NOTE: Since voltage can vary from one power outlet to another, setting the pressure adjustment based
on amp draw will extend the life of the motor by keeping the current within the correct range.

Pressure Adjustment Knob – Adjusts outlet pressure between 400 – 1200 psi. Note: you must
trigger the tool and spray to see adjustment of pressure. Clockwise increases and counterclockwise
decreases pressure. Let the pump run for about one minute, then adjust the pump using the ammeter
for maximum pressure (set at the break line between green and yellow). For lower pressure, down to
400 psi, simply turn the knob counterclockwise - while spraying - and watch the pressure gauge.

High Pressure Quick Disconnect – Attachment for high pressure solution line.

Auto-Dump Hose Fitting – Male garden hose fitting to attach dump hose.

Direct Feed-Hose Fitting – Female garden hose fitting to attach the direct water feed-hose.
The feed hose has a chemical siphon system and backflow preventer at the faucet end of hose.

Oil Level View Port - Allows viewing of the pump oil level sight-gauge.

SWITCH PLATE CONTROLS:

(refer to Figure 1)

Vacuum I Switch (1): Turns on/off vacuum motor I.

Vacuum II Switch (2): Turns on/off vacuum motor II.

Dump Pump Switch (3): Turns on/off dump pump. Float switch on
recovery tank automatically turns the pump on when the
solution level in the tank reaches a pre-set level AND the switch is on the ON
position.

High Pressure Pump Switch (4): Turns on/off the high
pressure (400-1200 psi) pump.

Dual Cord Sensor Light (5): The green light will turn on only when the
two power cords are plugged into separate circuits.

Hour Meter (6): Keeps track of the overall time the pump has been in use.

FIGURE 1

U.S. PRODUCTS

O

O

HIGH

PRESSURE

O

I

I

I

O

I

1

2

3

4

5

6

Advertising