American Dryer Corp. MLG31PCA User Manual

Page 13

Advertising
background image

9

1. The dryer must be installed on a sound level floor capable of supporting its weight. Carpeting must be

removed from the floor area that the dryer is to rest on.

IMPORTANT: “The dryer must be installed on noncombustible floors only.”

2. The dryer must not be installed or stored in an area where it will be exposed to water or weather.

3. The dryer is for use in noncombustible locations.

4. Provisions for adequate air supply must be provided as noted in this manual (refer to Fresh Air Supply

Requirements in Section D).

5. Clearance provisions must be made from noncombustible construction as noted in this manual (refer to

Dryer Enclosure Requirements in Section C).

Even though a 12-inch (30.48 cm) clearance is acceptable, it is recommended that the rear of the dryer be
positioned approximately 2 feet (0.61 meters) away from the nearest obstruction, i.e., wall, for ease of
installation, maintenance, and service. (Refer to the illustration below.)

6. Provisions must be made for adequate clearances for servicing and for operation as noted in this manual

(refer to Dryer Enclosure Requirements in Section C).

7. Dryer must be exhausted to the outdoors in an area where correct exhaust venting can be achieved as

noted in this manual (refer to Exhaust Requirements in Section E).

8. Dryer must be located in an area where correct exhaust venting can be achieved as noted in this manual

(refer to Exhaust Requirements in Section E).

IMPORTANT: Dryer should be located where a minimum amount of exhaust duct will be necessary.

Advertising