Type of gas, M lg31pca – American Dryer Corp. MLG31PCA User Manual

Page 26

Advertising
background image

22

2. Technical Gas Data

a. Gas Specifications

*

Measured at gas valve pressure tap when gas valve is on.

W.C. = Water column in inches.

b. Natural Gas

Regulation is controlled by each gas valve’s internal regulator. Incoming supply pressure must be
consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches (29.9 mb) water
column pressure.

c. Liquid Propane (L.P.) Gas

Dryers made for use with L.P. gas have the gas valve’s internal pressure regulator blocked open so that
the gas pressure must be regulated upstream of the dryer. The pressure measured at each gas valve
pressure tap must be a consistent 10.5 inches (26.1 mb) water column. There is no regulator or
regulation provided in an L.P. dryer. The water column pressure must be regulated at the source (L.P.
tank) or an external regulator must be added to each dryer.

TYPE OF GAS

NATURAL

LIQUID PROPANE

Manifold Pressure*

3.5 inches W.C.

8.7 mb

10.5 inches W.C.

26.1 mb

In-Line Pressure

6.0 - 12.0 inches W.C.

14.92 - 29.9 mb

11.0 inches W.C.

27.4 mb

Shaded areas are stated in metric equivalents

M LG31PCA

Gas Inlet Size (each basket/tumbler)

1/2” N.P.T.

Btu/hr Input (each basket/tumbler)

68,000

17,136 kcal/hr

Btu/hr Input (total for both baskets/tumblers)

136,000

34,272 kcal/hr

N.P.T. = National Pipe Thread