Section 5. Options For RS-232 Interface


Figure 5-7. Document Size Limit

Figure 5-8. Clear and Reset to Default


Download Option –
All RS232 Models

This drop-down menu selects what is to be downloaded to the MICR; either everything specified
in the dialog box (All) or just the format information (Only Format/Flex).

Upload Configuration From MICR – All RS232 Models

This button retrieves the current configuration from the MICR Reader to the dialog box. This
function may be used to verify or modify the current configuration of a MICR Reader.

Download Configuration To MICR – Subset, Fullset

This button downloads the portion of the settings in the Download Option selected.

Switches (SWA, SWB, SWC) – All RS232 Models

These boxes are for status only. As each option in the dialog box is checked or changed, the
switch setting in the appropriate box will change.

Switch HW – Fullset, Plus, MICRImage

This box is for status only. As each option in the dialog box is checked or changed, the switch
setting will change.