Suction extension setup (optional), Remote suction set setup, Remote suction set setup (optional) – Wagner Project Sprayer User Manual

Page 6

Advertising
background image

English

6

Remote Suction Set Setup (optional)

1. Remove the material container from the pump housing

by turning the pump housing ring counterclockwise.

7. Submerge the suction tube assembly into the material

container and attach the container clip (l) to the side

to hold it securely. Make certain the return line (m) is

inside the container.

3. Place a few drops of household oil down the intake (a)

and return (b) openings in the pump housing.

5. Push the remote suction hose onto the intake and return

ports of the dual hose fitting. The larger hose (f) goes

onto the intake port (g).

2. Remove the suction tube.

4. Push the dual hose

fitting (c) into the intake

and return openings

on the bottom of the

housing. The fitting

with the ridge (d) goes

into the return opening.

Twist the pump housing

ring (e) clockwise to

tighten the dual hose

fitting into place.

6. Slide the intake hose [(h), the larger hose] through

the container clip (i). You may need to pull the hoses

slightly apart.

Push the intake hose onto

the suction tube so that it

is flush with the ridge (j).

Make certain that the intake

filter (k) is in place on the

suction tube.

(m)

(l)

(g)

(f)

(d)

(c)

(e)

(a)

(b)

(i)

(h)

(j)

(k)

Advertising