TABLE I FLOW CONFIGURATIONS

4.

OPERATING INSTRUCTIONS

The SMV motorized valve requires a +12VDC power supply with a minimum
current rating of 800 mA. The operating power and valve control signals are
supplied via the 9-pin "D" connector located at the side of the valve.

The SMV motorized valve has three modes of operation: Valve Active
(Auto), Valve OFF Control and Valve Purge (Open).

4.1 Valve Active (Auto)

For normal operating in Auto mode the motorized valve requires at least two
control signals:

l Direction (12Vdc CMOS compatible logic level, pin 8 on the 9-pin "D" connector)

l Speed (0-2.5 VDC analog signal, pin 4 on the 9-pin "D" connector)

When direction is LOW (GND) valve goes down (closes), when direction is
HIGH valve goes up (opens). The "speed" voltage on pin 4 determines how
quickly the valve will operate. The signal amplitude for "speed" control signal
must remain within the limits of 0 to +2.5 VDC. The 2.5 Vdc input signal cor-
responds to approximately 250 steps per second. With resolution of the step-
ping motor of 0.00025"/step it results in a maximum speed about 0.0625"/sec.

6

MODEL

NUMBERS CONSTRUCTION

MAXIMUM FLOW RATE

(at 20 psi diff. pressure, 70

F

F)

Cv

CONNECTIONS

AIR

WATER

sL/min

scfh

L/min

GPM

SMV20-A

Aluminum

200

424

5.6

1.48

0.336

3/8”

SMV20-S

316 stainless

steel/PTFE

200

424

5.6

1.48

0.336

3/8”

SMV30-A

Aluminum

500

1060

14.2

3.75

0.855

1/2”

SMV30-S

316 stainless

steel/PTFE

500

1060

14.2

3.75

0.855

1/2”

SMV40-A

Aluminum

1000

2119

28

7.4

1.735

3/4” FNPT

SMV40-S

316 stainless

steel/PTFE

1000

2119

28

7.4

1.735

3/4” FNPT