5 dallas 1-wire bridge, 6 manual override – Matrix Orbital PK162-12 User Manual

Page 15

Advertising
background image

-

GND

+

MAX: 20 mA, +5Vdc

Figure 13: General Purpose Output

WARNING If connecting a relay, be sure that it is fully clamped using
a diode and capacitor in order to absorb any electro-motive force (EMF)
which will be generated.

2.5 Dallas 1-Wire Bridge

In addition to the six general purpose outputs the PK162-12 offers a Dallas 1-wire bridge, to allow for

an additional thirty two 1-wire devices to be connected to the display. See Section 8.1 on page 32.

Figure 14: Dallas 1-Wire Bridge

2.6 Manual Override

The Manual Override is provided to allow the PK162-12 to be reset to factory defaults. This can be

particularly helpful if the display module has been set to an unknown baud rate or I

2

C Slave Address and

you are no longer able to communicate with it. If you wish to return the module to its default settings you
must:

1.

Power off the display module.

Matrix Orbital