3 data lock – Matrix Orbital PK162-12 User Manual

Page 47

Advertising
background image

Syntax

Hexadecimal

0xFE 0x93 [switch]

Decimal

254 147 [switch]

Parameters

Parameter

Length

Description

switch

1

0: Do not remember, 1: Remember

Description

This command allows you to switch the remember function on and off.
To use the remember function, set remember to on, then set all of the
settings that you wish to save, settings that are listed as ’Remember:
Yes’ support being saved into the non-volatile memory. After you have
set all of the commands that you wish to save, you may then cycle the
power and check the display settings to ensure that all the settings have
been saved. If you wish to use remember again after cycling the power,
you must set it to on again.

NOTES

Writing to non-volatile memory is time consuming and slows down the operation of
the display.

Non-volatile memory has a ‘write limit’ and may only be changed approximately
100,000 times.

Remembered

No

Factory Default

Do not remember

11.3 Data Lock

Syntax

Hexadecimal

0xFE 0xCA 0xF5 0xA0 [level]

Decimal

254 202 245 160 [level]

Parameters

Parameter

Length

Description

level

1

Sets the data lock level

Matrix Orbital

PK162-12

43

Advertising