7 set debounce time, 8 set auto repeat mode – Matrix Orbital PK162-12 User Manual

Page 42

Advertising
background image

Syntax

Hexadecimal

0xFE 0x45

Decimal

254 69

ASCII

254 “E”

Description

This command clears any unread key presses. In a menu application, if
the user presses a key which changes the menu context, any following
key presses may be inaccurate and can be cleared out of the buffer be-
tween menu changes to prevent jumping around the menu tree. It may
also be used, in effect, to reset the keypad in case the host application
resets for whatever reason.

Remembered

No

9.7 Set Debounce Time

Syntax

Hexadecimal

0xFE 0x55 [time]

Decimal

254 85 [time]

ASCII

254 “U” [time]

Parameters

Parameter

Length

Description

time

1

Debounce time in increments of
6.554ms (0 - 255).

Description

This command sets the time between key press and key read. All key
types with the exception of latched piezo switches will ’bounce’ for a
varying time, depending on their physical characteristics. The [time]
value is in increments of 6.554ms. The default debounce time for the
module is 8 (about 52ms), which is adequate for most membrane key-
pads.

Remembered

Yes

Factory Default

8

9.8 Set Auto Repeat Mode

Matrix Orbital

PK162-12

38