Installation, Commissioning of Parallel Grippers

2-jaw parallel grippers

ID 1104573 Operating Manual RPP; RPP-A
Röhm GmbH, Dillingen Works Röhmstr. 6, 89407 Dillingen/Donau, GERMANY, Tel. (49)9071/508-0

Page 27 of 37

RPP/ RPP-A

Installation of the inductive proximity switches

Poll: Gripper open

1) Push the proximity switch under jaw 2 into the sensor holder up to the stop and secure it with

the clamping screw.

2) Move the gripper to position "OPEN" and test the function. Works setting: "Signal". If no

signal appears, a fine adjustment of the shifting block can be carried out at the adjustment
spindle. The shifting block is fixed from the outside with a clamping screw. Use a screwdriver
T8 (Torx size 8) for loosening and tightening.

The clamping position poll for inner gripping is adjusted to the respective workpiece using the
adjustment spindle.

Poll: Grippers closed

1) Push the proximity switch under jaw 2 into the sensor holder up to the stop and secure it with

the clamping screw.

2) Move the gripper to position "CLOSED" and test the function. Works setting: "Signal". If no

signal appears, a fine adjustment of the shifting block can be carried out at the adjustment
spindle. The shifting block is fixed from the outside with a clamping screw. Use a screwdriver
T8 (Torx size 8) for loosening and tightening.

The clamping position poll for inner gripping is adjusted to the respective workpiece using the
adjustment spindle.

Ind. Nährungsschalter

Backe 1

Backe 2

Axialer Sensoranschlag

Sensorhalter

Klemmschraube

Spannschraube

Verstellspindel

Nährungsschalter 1

Nährungsschalter 1

Verschiebeklotz

Advertising