Installation, commissioning of centric grippers – ROHM RZP / RZP-A 3-jaw centric gripper User Manual

Page 28

Advertising
background image


Installation, Commissioning of Centric Grippers

3-jaw centric grippers

ID 1104572 Operating Manual RZP; RZP-A
Röhm GmbH, Dillingen Works Röhmstr. 6, 89407 Dillingen/Donau, GERMANY, Tel. (49)9071/508-0

Page 28 of 39

RZP/ RZP-A

Caution:

The energy supply must be switched off during installation of the gripper. Observe

also the safety precautions. Please refer to the catalogue for the connection dimensions of the
respective gripper size.

Installation of Gripper RZP / RZP-A

1. Position the gripper over the two positioning bores in the flange using the straight pins

contained in the accessories kit.

2. Bolt on the gripper from above using 3 mounting bolts supplied.

Please observe the specified tightening torques.

3. With hoseless direct connection, pay attention to a clean connection surface. Use the

corresponding gaskets from the accessories kit.

4. During installation with compressed air screw fitting, pay attention to leak tightness of the

fitting.

Caution! When using hoseless direct connections, remove the grub screws and close off the
ports not used using suitable blind plugs.

5. Installation and adjustment of the polling sensors.

See "Installation of the proximity sensors and magnetic switches"

Function check

1. Actuate the gripper and test the stroke end positions of the jaws.

2. Check the sensor signal.

3. Check this function also with the workpiece.

Anschraubfläche

M5; G1/8"; G1/4"- Gewinde für
Pneumatikanschluss

Sperrluftanschluss

Durchgangsbohrung für Anbau
des Greifers von unten

Für schlauchlosen
Direktanschluss von unten

Passbohrung zur
Zentrierung des Greifers

Advertising