Installation, Commissioning of Centric Grippers

3-jaw centric grippers

ID 1104572 Operating Manual RZP; RZP-A
Röhm GmbH, Dillingen Works Röhmstr. 6, 89407 Dillingen/Donau, GERMANY, Tel. (49)9071/508-0

Page 31 of 39

RZP/ RZP-A

Installation of the magnetic field sensors

Poll: Gripper open

1) Position the gripper in position "OPEN"

2) Push magnetic field sensor 1 with the mounting bracket to the front into the C-groove in

gripper body (item 1) up to the stop and then pull the sensor out again slowly until it switches.

3) Fix the magnetic switch in this position by clamping it by tightening the grub screw in the C-

groove. (max. 0.1 Nm)

4) Test the function by opening and closing the gripper

Poll: Grippers closed

1) Position the gripper in position "CLOSED"

2) Push magnetic field sensor 2 with the mounting bracket to the front into the C-groove in

gripper body (item 1) up to the stop and then pull the sensor out again slowly until it switches.

3) Fix the magnetic switch in this position by clamping it by tightening the grub screw in the C-

groove. (max. 0.1 Nm)

4) Test the function by opening and closing the gripper

Poll: Workpiece gripped

Outer gripping

1) Clamp the part to be gripped

Proceed as described under "Gripper closed" from points 2-4.

Inner gripping

2) Clamp the part to be gripped

Proceed as described under "Gripper open" from points 2-4.

Backe 1

Backe 3

Backe 2

Magnetfeldsensor 1
(Greifer geöffnet)

Körper

Id.1083570 Magnetfeld-Sensor mit