The example shows an aircraft with lift/drag ratio 8. The necessary lift/drag ratio to the goal
is 6.3. The aircraft symbol is around 2.3 units above the point of best glide.
The strategy is, to hold the symbol in the crossover during the final glide. In order to hold
something reserve, experienced pilots will fly rather above the point of best gliding. During
thermalling the symbol remains in the center. As long as the deviation is larger than approx.
20 lift/drag ratios, the symbol appears grey in the center. Below that margin, the symbol
disappears to approximately 20 lift/drag ratios deviation. With approximately 6 lift/drag ratio it
appears then again from down in the window. If it comes upward over the delimitation, it
appears again grey.
A small arrow appears ^ above with the increase as a heading assistance, if track and
bearing are within +/- 10°. When sinking the arrows < ^ > indicate a recommendation, where
one should hold. If the symbol leaves the range of approximately plus minus 60°, the symbol
is grey again. One should switch then with the Esc key to the Vario screen, in order to see
the compass with the direction markers.

1.6 Main Setup Menu


Flightmemory

List of the flights in memory.

Waypoints

List of the waypoints with the possibility to edit waypoints and
coordinates

Routes

List of the routes with the possibility to edit

Restricted Areas

List of the restricted areas with the possibility to edit

Simulation

Here you can simulate most of the important flight parameters.

Basic Settings

Here you can change the most important parameters

Factory Settings

Only for service

Opt. SW-Packages

Here you can enable SW packages you bought from Flytec.

1.7 Basic Settings


A series of settings permit the unit to be programmed according to the user’s wishes. Every
pilot can realize his/her own ideas. If too much information bogs you down and causes
confusion, it is always possible to reset the unit at Basic Settings/ Init EEPROM, which are
the manufacturer’s tested basic settings. You are basically starting again.
But please note!

All WP and routes will be a deleted too. As a minimum, settings possible

and default values set will be shown at the setting points. Should these values be changed,
you move to the change mode by pressing Enter. The value to be changed will blink and can
be modified with the help of the ▼ and ▲ keys. Pressing the Enter key confirms the new
value. Pressing the ESC key recalls the previous setting.


Term Meaning

Referen
ce

Factory Setting

Display contrast

Range 0 ... 100 %

70 %

Record-Interval

Time interval per recorded (track
log) point

10 Sec

Recording mode

Autom. or manual flight recording

Aut.

Digital Variomode

Averager ; Averager time delay

1 sec 30 sec

Vario tone

Frequency of Climb and Sink tone,
Pitch Modulation, Acoustic
Integrator

1200 Hz ; 700 Hz
Mod = 5 ;Pi=3; 8

Battery type

Type of battery used. This has an
influence on the bargraph and the
switching thresholds

Alcaline

Advertising