Installation

(For Qualified Installers Only)

1 5

© Travis Industries

4080725

1 0 0 - 0 1 1 5 4

Installation Example: Interior Vertical Installation

Vent

Clearance*

Type "L" Vent

6” Minimum

Floor Protection

2”

Minimum

9” Minimum

Outside

Air

(optional)

Floor Protection

24” Minimum

Insulation

must maintain

clearance*.

Outside air may be drawn from

a ventilated crawl space.

2” Min.

Vent

Clearance*

Ceiling Support / Fire Stop Spacer

Roof Flashing

Storm Collar

Vertical Cap

Vent must

maintain

clearance to

combustibles*.

“L” Vent

Seal each vent
section (including
adapters, elbows,
etc...) by injecting a
liberal amount of
500° F. RTV
silicone into the gap
between sections.

500

° F. RTV

Silicone

“Tee”

*

Install vent at clearance specified by the vent manufacturer.