Specifications, Heating specifications, Dimensions – Avalon Stoves Astoria PS User Manual

Page 6: Electrical specifications, Fuel, Epa compliance

Advertising
background image

6

Specifications

© Travis Industries

4080725

1 0 0 - 0 1 1 5 4

Heating Specifications

Approximate Maximum Heating Capacity (in square feet)* ........................................800 to 2,250 Sq. Feet

Burn Rate (Pounds per Hour)**............................................................................1.7 to 5.5

Maximum Burn Time on Low Burn** ......................................................................67.5 Hours

Hopper Capacity ..............................................................................................115 Pounds

*

Heating capacity will vary depending on the home's floor plan, degree of insulation, and the outside temperature. It is also affected
by the fuel size, quality, and moisture level.

**

Small pellets will increase or decrease the stated burn rates and burn times. Differences of plus or minus 20% depending on fuel
quality may occur.

Dimensions

Weight: 250 Lbs.

Air Inlet

(1-3/4"

Outside

Diameter)

4"

Diameter

Exhaust

10-1/2”

17-5/8"

1/2"

7-1/4"

Center

Line

33-3/8"

26-1/2"

28"

This tab is for

the scraper

rod tool.

Electrical Specifications

Electrical Rating.........................................................................................115 Volts, 3.6 Amps, 60 Hz

Watts During Start-Up Sequence ...................................................................400 (approximately)

Watts During Operation ...............................................................................180 (approximately)

Fuel

• This heater is designed and approved for pelletized wood fuel or a mixture up to 50% corn, 50% pellets.

See page 25 for details on using a corn pellet mix.

EPA Compliance

This heater has been tested exempt from EPA Phase II Requirements by OMNI-Test Laboratories, Inc.