Installation Example: Class A Chimney Retrofit

Vent

Clearance*

Type "L" Vent

6” Minimum

Floor Protection

2”

Minimum

9” Minimum

Outside

Air

(optional)

Floor Protection

Outside air may be drawn from

a ventilated crawl space.

2” Min.

Vent

Clearance*

Class A Chimney Ceiling Support

Roof Flashing

“L” Vent to Class A Chimney Adapter

Class A Chimney

“L” Vent

Storm Collar

Class A Chimney must

maintain clearances outlined

in the chimney’s installation

instructions (usually 2”).

“Tee”

Seal each vent
section (including
adapters, elbows,
etc...) by injecting a
liberal amount of
500° F. RTV
silicone into the gap
between sections.

500

° F. RTV

Silicone

*

Install vent at clearance specified by the vent manufacturer.