Principle of operation – Samlex America SAM-3000-12 User Manual

Page 6

Advertising
background image

4 | SAMLEX AMERICA INC.

SAMLEX AMERICA INC. | 5

SECTION 2 |

Description, Features &

Principle of Operation

Load controlled cooling fan

Cooling is carried out by convection and by forced air circulation by load-controlled fan.
The fan will normally be OFF and will be switched ON automatically at the following
loads:

SAM-1000-12

28 to 32 Watts

SAM-1500-12, SAM-2000-12 & SAM-3000-12

90 to 110 Watts

This will reduce energy consumption by the fan and will increase overall efficiency

principle of operation

Conversion of 12 VDC from the battery / other DC source to 115 VAC takes place in 2
stages. In the first stage, the 12 VDC is converted to high voltage DC (around 160 VDC)
using high frequency switching and Pulse Width Modulation (PWM) technique. In the
2nd stage, the 160V high voltage DC is converted to 115V, 60 Hz Modified Sine Wave AC.
(Note: 115 V is the RMS value of the Modified Sine Wave AC voltage. The peak value of
the Modified Sine Wave AC voltage will be equal to the value of the above high voltage
of around 160V. See the Fig 2.1 below)

modified Sine Waveform -

characteristics & comparison with pure Sine Waveform

Please refer to Fig 2.1 below which shows one cycle of Modified Sine Wave and Pure Sine
Wave for comparison.

TIME

180

160

140

120

100

80

60

40

20

0

20

40

60

80

100

120

140

160

180

Modified Sine

Wave sits at

0V for some

time and then

rises or falls

Sine Wave

Modified Sine Wave

Pure Sine Wave

crosses 0V

instantaneously

Legend

V +

V -

115 RMS

Fig 2.1 Modified Sine Wave and Pure Sine Wave - Comparison

11002-SAM-1000-1500-2000-3000-12-0814.indd 6

14-08-12 9:59 AM