3 optical specifications, 1 laser head specifications, 2 sensor head specifications – Campbell Scientific PWS100 Present Weather Sensor User Manual

Page 20: 4 environmental specifications, 5 cs215-pws specifications, 6 measurement capabilities and limitations, 1 visibility measurements

Advertising
background image

Section 5. Specifications

5.3 Optical Specifications

5.3.1 Laser Head Specifications

Laser Source:

Near-infrared (IR) diode, eye safe Class 1M
unit output

Peak Wavelength:

830 nm

Modulation Frequency:

96 kHz

Laser Head Lens Diameter: 50 mm (1.97 in)

5.3.2 Sensor Head Specifications

Receivers:

Photodiode with band pass filters

Spectral Response:

Maximum spectral sensitivity at 850 nm, 0.62
A/W (0.6 A/W at 830 nm)

Sensor Head Lens Diameter: 50 mm (1.97 in)

Lens Check Light Source:

Near-IR LED

5.4 Environmental Specifications

Standard Operating
Temperature Range:

-25

° to +50°C

Optional Extended Operating
Temperature Range:

-40

° to +70°C

Relative Humidity Range:

0 to 100%

IP Rating:

IP 66 (NEMA 4X)

5.5 CS215-PWS Specifications

Please refer to the CS215 manual or product brochure for the specifications.

5.6 Measurement Capabilities and Limitations

5.6.1 Visibility Measurements

Visibility Range:

0 to 20,000 m (0 to 65,620 ft)

Visibility Accuracy:

± 10% (0 to 10,000 m)

Measurement Interval:

User selectable from 10 seconds to 2 hours

5-2

Advertising